The role of capacitor resistance in three-phase motor drive.

Hardware design
十月 29, 2020 by Rudi 867

The picture shows a phase in a motor drive. Are C4B and R5B absorbing spike voltages? The voltage is 60V. How is this type selected?

所有评论

user image

Hamilton 发表于 October 29, 2020

Filtered, filter high frequency interference;

In addition, inside the MOS tube: there is a capacitor between GS;

The capacitance value is calculated according to the signal frequency.

0
user image

Auston 发表于 October 29, 2020

The capacitor is an absorbing capacitor, which needs to be selected according to the voltage spike generated by the parasitic inductance on the bus. The high-frequency non-inductive capacitor should be placed as close as possible to the MOSFET on the PCB.

That resistor seems to be the discharge resistor of the bus capacitor, the circuit is missing part.

0
user image

Marcia 发表于 October 29, 2020

The resistor is to provide a virtual ground for the upper bridge drive, allowing the upper bridge to open normally when no load is connected.