The single-ended flyback switching power supply will burn the fuse.

Hardware design
十一月 09, 2020 by Deja 2167

As shown in the figure, u1 is an ac-dc power supply module. The current problem is that fuse f1 sometimes burns out. Is there any way to solve it, the normal working current is only a few hundred mA.

所有评论

user image

Leona 发表于 November 9, 2020

Is it burned after use? Is the motor followed?

0
  • Deja

    Deja 发表于 November 9, 2020

    The next one is the motor, which was burned out when the power was turned on.

  • 您需要登录才能回复。 登入 | 注册

user image

Reggie 发表于 November 9, 2020

Measure the current at the moment of power-on. Is the slow tube or fast tube used for the fuse?

0
  • Deja

    Deja 发表于 November 9, 2020

    At present, it is a bit difficult for the company to measure the power-on current. The fuse is an ordinary glass tube, and it should be a fast melting.

  • 您需要登录才能回复。 登入 | 注册

user image

Dorothy 发表于 November 9, 2020

Change the slow tube, count 3-5 times the current when the motor starts, and reselect the fuse.

0